Toolshed Ltd Company Logo Toolshed Ltd

Fluke 3540 FC KIT Three-Phase Power Monitor

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price

Browse by Category

Contact us

Toolshed Ltd
[Singapore]

Address
150 South Bridge Rd, #B3-30 Fook Hai Building Singapore Singapore
Phone
65-6533-2066
Contact name
Hendrik Norsan

Quick Information

  • Brand Name: Fluke
  • Place of Origin: Singapore
  • Model Number : 3540 FC
  • Power : Electronic
  • Usage : Vibration Testing Machine
  • :

Description

Fluke 3540 FC KIT Specifications

Environmental Specifications
Operating Temperature32 to 113°F (0 to 45°C)
Storage Temperature-4C to 140°F (<20 to 60°C), with battery: -4 to 122°F (-20 to 50°C)
Operating Humidity<50°F (<10°C) non condensing
50 to 86°F (10 to 30°C) ≤95%
86 to 104°F (30 to 40°C) ≤75%
104 to 113°F (40 to 45°C) ≤45%
Operating Altitude6500' (2000 m) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage Altitude39,000' (12,000 m)
IP RatingIEC 60529:IP50, in connected condition with protection caps in place
VibrationMIL-T-28800E, Type 3, Class III, Style B
Safety IEC 61010-1IEC mains input: Overvoltage Category II, Pollution Degree 2
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
Electromagnetic Compatibility (EMC)International: IEC 61326-1: Industrial
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless Radio with AdapterFrequency range: 2412 to 2462 MHz
Output power: <100 mW
Electrical Specifications
Single and Three-Phase TopologiesWiring configurations: 1-Φ, 1-Φ IT, Split-phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies)
Voltage InputsNumber of inputs: 4 (3 phases and neutral)
Maximum input voltage: 1000 Vrms (1700 Vpk) phase to neutral
Input Impedance10 MΩ each phase to neutral
Bandwidth42.5 Hz to 3.5 kHz
Scaling1:1, variable
Current InputsNumber of inputs: 3, mode selected automatically for attached sensor
Current Sensor Output VoltageClamp: 500 mVrms / 50 mVrms; CF 2.8
Rogowski coil: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Bandwidth(-3 dB)42.5 Hz to 3.5 kHz
Scaling1:1 and variable
Data Acquisition Resolution16-bit synchronous sampling
Sampling Frequency10.24 kHz at 50/60Hz, synchronized to mains frequency
Input Signal FrequencyMains 50/60 Hz (42.5 to 69 Hz)
Data StorageInternal flash memory (not user replaceable)
Memory SizeTypical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements.
Measured ParametersVoltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF
Averaging Interval1 s
Total Harmonic DistortionTHD for voltage and current is calculated on 25 harmonics
Calculated min/max values timesVoltage: Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)
Current: Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz)
Power: 200 ms
InterfacesUSB-A: Firmware updates, max. supply current: 120 mA
WiFiSupported modes: Direct connection and connection to infrastructure
SecurityWPA2-AES with pre-shared key
Power SupplyVoltage Range: Nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input
Mains PowerNominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input
Power ConsumptionMaximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Standby Power<0.3 W only when powered using IEC 60320 input
Efficiency≥68.2 % (in accordance with energy efficiency regulations)
Mains Frequency50/60 Hz ±15 %
Battery PowerLi-ion 3.7 V, 9.25 Wh, customer-replaceable
On-Battery RuntimeUp to 4 hr (up to 5.5 hr in energy saving mode)
Charging Time<6 hours
General Specifications
Color LCD Display4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty3540 FC and built-in power supply 2 years (battery not included)
Accessories1 year
Calibration Cycle2 years
Dimensions3540 FC: 7.8 x 6.6 x 2.2" (19.8 x 16.7 x 5.5 cm)
Detachable Power Supply: 5.1 x 5.1 x 1.8" (13.0 x 13.0 x 4.5 cm)
3540 FC with Power Supply Attached: 7.8 x 6.6 x 4.0" (19.8 x 16.7 x 9 cm)
Weight2.5 lb (1.1kg)
Tamper ProtectionKensington lock


Price

  • Delivery Port : Changi

Packaging & Delivery

  • Packing :New Box
  • Delivery Lead Time : 2-3

Product Image

  • Fluke 3540 FC KIT Three-Phase Power Monitor image

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Hendrik Norsan
Toolshed Ltd
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Testing Equipment
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838